top of page
PhoenixTM 6Ch Teflon Coating System

PhoenixTM 6Ch Teflon Coating System

SKU : HTS-01-090-6 SIGMA

Application : PTFE, non-stick and high temperature coating, CQI-12 coating system assessment

  • PTM1-206-K SIGMA  l  6 Channel Data Logger, temperature measuring range -100°C to +1370°C, type K, standard temperature operation.

     

    Accuracy +/- 0.3°C, resolution 0.1°C.

    Total memory 3.8M data points of non-volatile memory over 6 channels.

    Sampling interval 0.2s to 60 minutes on all selected channels.

    Maximum ambient operating temperature 80°C.

    Original calibration certificate and correction factors stored in memory for access as required.

    Up to 1000 hours battery life from 2 x ‘AA’ Alkaline Standard Batteries.

    Bluetooth connectivity,

    USB communication cable included.

    Dimensions: 200mm(L) x 70mm(W) x 20mm(H).

Related Products

bottom of page